{
  "version": "Black / Silver Editorial V1",
  "type": "controlled design rendering; not production photography",
  "product_identity": "TP-032LH black/silver. Owner-approved Kevin 032LH-V3 pixels preserved; CAD used only for disclosed tilt demonstration.",
  "confirmed": {
    "rated_power_w": 1400,
    "filter_grade": "H13 HEPA",
    "manual_tilt": "15 degrees forward and backward",
    "fan_modes": "8 normal + Boost + Sleep",
    "heating_levels": 3,
    "horizontal_oscillation": "up to 90 degrees",
    "timer": "1–9 hours",
    "fan_speeds": "10 airflow settings: 8 regular speeds + Sleep (LL) + Boost (HH). Not 10 regular speeds.",
    "factory_reported_noise_db": {
      "value": 52,
      "display": "≤52 dB",
      "source": "Owner relayed factory measurement on 2026-11-06",
      "qualification": "Factory-reported result; weighting, distance, operating mode and test protocol not supplied; not an all-conditions guarantee."
    }
  },
  "pending": {
    "US_voltage_frequency": "120V appears in draft manual; final voltage/frequency not verified",
    "product_dimensions": "A0 19.5×19.5×68.5 cm vs latest manual 20×20×68 cm. Actual production sample governs.",
    "filter_geometry": "Uses supplied illustration; exact cartridge dimensions/seals require production sample",
    "noise_airflow": "Independent standardized airflow-volume and acoustic test reports not supplied; internal sample observations are explicitly qualified."
  },
  "packaging_estimate": {
    "carton_cm": [
      22,
      22,
      72
    ],
    "units_per_carton": 1,
    "gross_kg_approx": 4,
    "volume_m3": 0.034848,
    "final_packed_sample_pending": true
  },
  "loading_calculation": {
    "method": "Floor(L/22) × floor(W/22) × floor(H/72); upright floor loading; no pallets, clearance or strength allowance. Not a shipping commitment.",
    "assumed_container_internal_cm": {
      "20GP": [
        590,
        235.2,
        239.5
      ],
      "40GP": [
        1203.2,
        235.2,
        239.5
      ],
      "40HQ": [
        1203.2,
        235,
        270
      ]
    },
    "theoretical_units": {
      "20GP": 780,
      "40GP": 1620,
      "40HQ": 1620
    }
  },
  "source_records": [
    "TP-032LH A0 manufacturer specification",
    "Latest Lily manual reconciliation dated 2026-11-05",
    "Owner-confirmed 1400W, H13 and +/-15 degree tilt",
    "Kevin PMC 032LH-V3 original source; supplied filter reference and STEP CAD",
    "Faryuan internal 050 / 046 / 032 air-speed and noise report, 2026-11-02, read online 2026-11-06",
    "Owner confirmation: factory measured 52 dB; owner measured approximately 48 dB"
  ],
  "source_url": "https://pmc.faryuan.biz/pmc/kevin/collections/pmc-folder-kevin-mw1zrlci-a8e56ed8",
  "performance_claims_pending": {
    "airflow_plus_15_percent": "Shown only in the owner-approved design proposal with an explicit pending-verification footnote. Not established by the internal air-speed readings; air speed is not airflow volume.",
    "noise_minus_10_percent": "Shown only in the owner-approved design proposal with an explicit pending-verification footnote. Not established as a loudness reduction; dB readings are logarithmic."
  },
  "internal_test_observations": {
    "date": "2026-11-02",
    "mode": "HH (Boost)",
    "TP-032LH": {
      "air_speed_m_per_s": 3.45,
      "noise_dBA": 47.2
    },
    "UML-046JR": {
      "air_speed_m_per_s": 3.45,
      "noise_dBA": 61.6
    },
    "observed_noise_difference_db": 14.4,
    "qualification": "Internal sample observations only. Distance, background noise, air-speed filter state and repeatability not recorded; not standardized laboratory performance claims."
  },
  "design_proposal_added": {
    "date": "2026-11-07T17:43:38.026416+00:00",
    "file": "15-airflow-noise-white-design.webp",
    "approved_for": "PMC design-library display in existing Kevin V3 and Editorial V1",
    "qualification": "Visual approval is not measurement validation; source image and visible footnote unchanged."
  }
}
