2 C19 + 4 C13
One 20A bank breaker
1U RACK DISTRIBUTION / 12 OUTLETS
Four C19.
Eight C13.
Both banks in view.
A compact distribution layout for compatible server, storage and network equipment. Two local current meters keep each bank visible from the same control side.
OUTLET SIDE
Original factory layout reference. No product geometry has been AI-generated.
ONE INPUT. TWO BANKS.
Read each meter.
Add the two readings.
Meter A reports Bank A. Meter B reports Bank B. The two outlet banks share one incoming supply, so their combined current must stay within the total limit.
This arrangement provides local bank visibility. It is not an independent redundant A/B power supply.
2 C19 + 4 C13
One 20A bank breaker
Illustrative readings. Proposed outlet-to-bank mapping must match the final factory wiring and labels.
CHECK THE CONNECTION
Match the outlet and the equipment.
Four C19 outlets accept compatible C20 plug-ended equipment cords. Check the cord and equipment ratings.
Eight C13 outlets accept compatible C14 plug-ended cords for suitable servers, switches and storage equipment.
The fixed input cable requires a matching, properly installed grounded supply. This PDU does not convert voltage.
For equipment rated for the supplied 208/240V AC voltage. Do not connect 120V-only equipment or defeat protective grounding.
DESIGN CONFIGURATION
Specifications at a glance.
| Outlet configuration | 4 x IEC C19 + 8 x IEC C13 |
|---|---|
| Input design | 208/240V AC, 50/60Hz, single phase |
| Input connection | NEMA L6-30P; suitable grounded L6-30R supply required |
| Input circuit / continuous total | 30A circuit / 24A maximum combined continuous load |
| Meters and bank breakers | 2 local AC current meters / 2 x 20A bank breakers |
| Proposed bank allocation | Each bank: 2 C19 + 4 C13; factory wiring confirmation pending |
| Continuous bank planning | Up to 16A per bank pending final assembly rating |
| Fixed input cable | 9.84 ft (3 m), 10 AWG, three-conductor copper |
| Mounting | 19-inch horizontal rack, 1U target; final dimensions pending |
The 16A per-bank planning value is 80% of a standard 20A breaker. A 100%-rated continuous assembly has not been established. At 24A total, apparent power is 4.99kVA at 208V or 5.76kVA at 240V; actual watts depend on power factor. Each outlet and cord rating also applies.
Production details awaiting factory confirmation
Final 1U height, mounting-hole spacing, depth, internal clearance, bank wiring, outlet/cable/assembly ratings, model identifier and complete-unit certification. Retail/master carton dimensions, packing quantities, net/gross weights and 20GP/40GP/40HQ loading quantities are also pending.
ENGLISH USER MANUAL
One A4 sheet.
Four folded panels.
Adapted from the existing 2U manual: safety, installation, both bank readings, load examples and support. Updated for the twelve-outlet 1U design and 3 m cable.
Print: A4 landscape, two-sided, actual size, flip on the short edge. Fold at the centre. Outside: 4 | 1. Inside: 2 | 3.
Factory-confirmation copy. Confirm final production facts before pack-in printing.

AMAZON US / ENGLISH LISTING DRAFT
Title and listing copy.
Prepared for review in PMC. This content has not been submitted to Amazon. Confirm the final SKU, ratings and production facts before use.
Product title
FARYUAN 1U Rack Mount PDU, 30A 208/240V, 12 Outlets (4 C19 + 8 C13), Dual Current Meters, Two 20A Breakers, NEMA L6-30P Plug, 9.8 ft 10 AWG Cord
144 charactersFive bullets
- 12 OUTLETS IN A 1U LAYOUT
Four C19 and eight C13 outlets support a mix of compatible servers, storage and networking equipment. All output outlets are on one side, with both current meters and bank controls on the other. Designed for horizontal mounting in a 19-inch rack.
- READ BOTH BANKS AT A GLANCE
Two local AC current meters show Bank A and Bank B separately. Add the readings to check total load. Use the bank labels to plan your connections and check both readings when adding equipment.
- 30A INPUT, 24A CONTINUOUS TOTAL
For compatible 208/240V AC equipment on a suitable 30A circuit. Combined continuous load must stay at or below 24A. Two 20A bank breakers do not create a 40A PDU. Follow the final nameplate, outlet and cord limits.
- L6-30P CONNECTION AND 10 AWG CABLE
The fixed 9.84 ft (3 m) 10 AWG input cable terminates in a NEMA L6-30P twist-lock plug. Requires a matching, properly installed L6-30R supply receptacle. This PDU does not convert voltage and is not for 120V-only equipment.
- LOCAL CONTROL FOR SMALL RACKS
A focused configuration for compatible server, storage and lab equipment where local current visibility matters. View both bank currents at the rack and distribute equipment across the labelled outlets. The two protected banks share one incoming supply.
Product description
Bring mixed rack equipment onto one compact distribution point. The FARYUAN 1U PDU design combines four C19 outlets and eight C13 outlets with two local current meters and two 20A bank breakers. Keep the outlet side with your equipment cables and read both banks from the control side. The fixed 3 m 10 AWG cable uses a NEMA L6-30P input. Connect only compatible 208/240V equipment, monitor each bank and keep the combined continuous load at or below 24A. This is one incoming supply split into two monitored banks, not redundant A/B input power.
VERSION LIBRARY
English detail artwork.
Six downloadable schematic panels, preserved as version V1.
Open all six detail panels and downloads →